Carbon in Fly Ash Analyzing System
  Product Introduction
Carbon in Fly 
Ash Analyzing System
Boiler Tube Leak 
Monitoring System
Multistage Steam Ejector 
for Air Extraction Unit
Power System 
Real-time Graphic Monitor
Thermal power station noise abatement project
Air Pre-heater 
Pulsing De-ashing System
Kraftwerk Kenngeichen System
Power Station Auxiliary System and Water Supply Distributed Control
Waste Water Treatment Engineering
Power Plant Water Treatment Engineering
  Introduction to the system

1) The system applies the internationally advanced non-ash-way
sectional measurement technology, with the fume flow field 
flowing in the flue as the object to be measured, let the microwave be vertical to the fume flowing direction and rapidly cross the whole flue field, and the measurement to ”°sectional ash sample”± is completed instantly (20ms). The successive on-line measurement is realized really.
2) It fundamentally avoids the problem for traditional 
microwave to measure coal products:
  • The problem of sampling representative
  • Solution of ash way jam
  • Quickness of measurement cycle
  • Influence of coal variety change

3) It applies high quality and adjustable microwave resource, which greatly enhance the anti-interfere of the system.
4) The optimized system design is simple and reliable, and operation is stable free of maintenance.
5) The colored liquid crystal display is of friendly interface and Win98 software platform is convenient for operation. 

  Realization of functions   Structure diagram
1. Real-time value and curve display
2. Average value and bar diagram display
3. Historical carbon content curve recollection
4. Communication function with DCS system
5. Carbon content data off-line skim
6. Carbon content threading alarming setting 
Signal collection self-inspection and alarming

  Technical parameters   Position of installation
Scope of measurement 0~30% (carbon content)
Error of measurement ”Ą0.3%(0~8% of carbon content)
”Ą05% (8~15% of carbon content)
<1.5% (carbon content >15%)
Frequency of measurement 30 sec 
System responding time<20ms 
Historical data remaining for 12 months
Power consumption 600W 220V/AC
Output signal 4~20mA/2 way isolated carbon content signal
2-way node signal (self-inspect & carbon-content threading alarm)
Communication Interface RS-485 standard


Measured point is installed at the vertical pipe section (or horizontal pipe section) between the outlet of the air preheater to inlet of the dust remover.